StrainMatic logo

StrainMatic®

Start

Imaging Polarimeters

German
Online Demonstration [HTML/Flash] More Downloads

Function

Automatic and Objective Measurement of the
Stress Birefringence in Glass and Plastics
and other Translucent Materials

StrainMatic M4/50 Inline

Features
and
Benefits

Applications

User Interface
with Result of a
Measurement

StrainMatic user interface (click to enlarge)
StrainMatic user interface (click to enlarge)
StrainMatic M3/M and M2/M

StrainMatic® M3
(left)

StrainMatic® M2
(right)

Technical
Data

StrainMatic® M3/250 StrainMatic® M2/250
main application glass and plastic products container glass
metering chamber approx. 465 x 450 x 350 mm (H/W/D) approx. 450 x 450 x 350 mm (H/W/D)
operating distance approx. 465 mm (fixed) approx. 100 - 450 mm, motor adjustment
illumination LED array, approx. 240 x 200 mm LED array, approx. 240 x 200 mm
image acquisition matrix camera (640 x 480 pixels) matrix camera (640 x 480 pixels)
image size max. 200 x 150 mm (with 16 mm lens) max. 200 x 150 mm (with 16 mm lens)
measuring results polarization angle (°)
temper number (ASTM C 148-00)
optical retardation (nm)
normalized optical retardation (nm/cm)
integrated stress (MPa)
polarization angle (°)
temper number (ASTM C 148-00)
optical retardation (nm)
normalized optical retardation (nm/cm)
integrated stress (MPa)
measuring range approx. 0 to 72 nm (standard mode)
approx. 0 to 290 nm (uni- or multi-directional)
approx. 0 to 2900 nm (with HOD module)
approx. 0 to 72 nm (standard mode)
approx. 0 to 290 nm (uni- or multi-directional)
approx. 0 to 2900 nm (with HOD module)
repeatability ±0,2 nm ±0,2 nm
interfaces Ethernet, USB, VGA/DVI Ethernet, USB, VGA/DVI
power supply 230 V, 50 Hz or 115 V, 60 Hz 230 V, 50 Hz or 115 V, 60 Hz
dimensions approx. 930 x 550 x 550 mm (H/W/D) approx. 1200 x 550 x 550 mm (H/W/D)

StrainMatic®
M4/100 (left)

StrainMatic®
M4/140 (right)

StrainMatic M4/100
StrainMatic M4/140

Technical
Data

StrainMatic® M4/100 StrainMatic® M4/140
main application optical materials, components optical materials, components
metering chamber approx. 200 x 450 x 450 mm (H/W/D) approx. 300 x 450 x 450 mm (H/W/D)
illumination LED array, approx. 200 x 160 mm LED array, approx. 200 x 160 mm
image acquisition matrix camera (1360 x 1024 pixels) with telecentric lens (100 mm aperture) matrix camera (1360 x 1024 pixels) with telecentric lens (140 mm aperture)
image size approx. 80 x 60 mm (0.06 mm/pixel) approx. 112 x 84 mm (0.08 mm/pixel)
measuring results polarization angle (°)
optical retardation (nm)
normalized optical retardation (nm/cm)
integrated stress (MPa)
polarization angle (°)
optical retardation (nm)
normalized optical retardation (nm/cm)
integrated stress (MPa)
measuring range approx. 0 to 72 nm (standard mode)
approx. 0 to 290 nm (uni- or multi-directional)
approx. 0 to 2900 nm (with HOD module)
approx. 0 to 72 nm (standard mode)
approx. 0 to 290 nm (uni- or multi-directional)
approx. 0 to 2900 nm (with HOD module)
repeatability ±0,1 nm ±0,1 nm
interfaces Ethernet, USB, VGA/DVI Ethernet, USB, VGA/DVI
power supply 230 V, 50 Hz or 115 V, 60 Hz 230 V, 50 Hz or 115 V, 60 Hz
dimensions approx. 860 x 550 x 550 mm (H/W/D) approx. 1120 x 550 x 550 mm (H/W/D)

StrainMatic®
M4/60 zoom (left)

StrainMatic®
M4/60 tube tester
(right)

StrainMatic M4/60 zoom
StrainMatic M4/60 tube tester

Technical
Data

StrainMatic® M4/60 zoom StrainMatic® M4/60 tube tester
main application optical materials and components tube glass
metering chamber approx. 150 x 550 x 550 mm (H/W/D) cell approx. 100 x 50 x 50 mm (H/B/T)
illumination LED, collimated LED, collimated
image acquisition matrix camera (1000 x 1000 pixels) with telecentric 4x zoom objective lens matrix camera (2050 x 2448 pixels) with telecentric lens (60 mm aperture)
image size approx. 44 x 44 mm (0.04 mm/pixel) to
approx. 11 x 11 mm (0.01 mm/pixel)
approx. 38 x 46 mm (0.02 mm/pixel)
measuring results polarization angle (°)
optical retardation (nm)
normalized optical retardation (nm/cm)
integrated stress (MPa)
polarization angle (°)
optical retardation (nm)
normalized optical retardation (nm/cm)
integrated stress (MPa)
tube wall stress (MPa)
measuring range approx. 0 to 72 nm (standard mode)
approx. 0 to 290 nm (uni- or multi-directional)
approx. 0 to 72 nm (standard mode)
approx. 0 to 290 nm (uni- or multi-directional)
repeatability ±0,01 nm ±1 MPa
interfaces Ethernet, USB, VGA/DVI Ethernet, USB, VGA/DVI
power supply 230 V, 50 Hz or 115 V, 60 Hz 230 V, 50 Hz or 115 V, 60 Hz
dimensions approx. 1150 x 650 x 650 mm (H/W/D) approx. 2300 x 940 x 480 mm (H/W/D)
StrainMatic M4/150 Stepper
StrainMatic M4/320

StrainMatic®
M4/150 stepper (left)

StrainMatic®
M4/320 (right)

Technical
Data

StrainMatic® M4/150 stepper StrainMatic® M4/320
main application optical materials and components optical materials and components
Sample dimensions max. 500 x 400 x 400 mm (H/W/D), 100 kg max. 300 x 500 x 500 mm (H/W/D), 100 kg
sample positioning XY table with automatic stitching Sample table with telescopic slide-out
illumination LED, collimated LED, collimated
image acquisition matrix camera (1000 x 1000 pixels) with telecentric lens (150 mm aperture) matrix camera (2048 x 2048 pixels) with telecentric lens (320 mm aperture)
image size approx. 105 x 105 mm (0.11 mm/pixel) approx. 320 mm diameter (0.16 mm/pixel)
measuring results polarization angle (°)
optical retardation (nm)
normalized retardation (nm/cm)
integrated stress (MPa)
polarization angle (°)
optical retardation (nm)
normalized retardation (nm/cm)
integrated stress (MPa)
measuring range ca. 0 bis 72 nm (standard mode)
ca. 0 bis 290 nm (uni- or multi-directional)
ca. 0 bis 72 nm (standard mode)
ca. 0 bis 290 nm (uni- or multi-directional)
repeatability ±0,01 nm ±0,01 nm
interfaces Ethernet, USB, VGA/DVI Ethernet, USB, VGA/DVI
power supply 230 V, 50 Hz or 115 V, 60 Hz 230 V, 50 Hz or 115 V, 60 Hz
dimensions approx. 1850 x 1800 x 1500 mm (H/W/D) approx. 2200 x 1100 x 800 mm (H/W/D)

References

Ardagh Glass Group
Saint-Gobain Oberland AG
Carl Zeiss Jena GmbH
SCHOTT AG
JENOPTIK Polymer Systems GmbH
Bayer MaterialScience AG
Leuze electronic GmbH + Co KG
Bauhaus-Universät Weimar, chair in steel building
Laser Zentrum Hannover e.V.

Application
Examples

Tableware
CD blank
Laboratory glass
Pharma vial
Container glass base
Container sidewall
Plastic optics
Light bulb
Flat glass
Building glass
Strain Disc
Glass brick
Glass lens
Bottle sidewall
Plastic film